FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
TABLE OF CONTENTS
SECTION 1. GENERAL DESCRIPTION
SCOPE OF MANUAL ........
ELECTRICAL CHARACTERISTICS. .........
PHYSICAL CHARACTERISTICS ...........
OPERATIONAL DESCRIPTION. ...........
DISPLAY 3 i i cee a el 8 aw we Be ee ew
DECIMAL POINT SELECTOR, ..........6.6+.
SERVICE CALLS ........ ae teee wee mse
CUSTOMER CONTACT ie; « 0 16: 6 1 io: © me yon ee mw ie
MACHINE CHECKOUT .......... ei
SERVICING DOCUMENTATION. .......+8.6+5
COMPUTER PRINTOUT (MDD)...........
LOGIC BLOCK DIAGRAM. .. . 6 se see ene
ENGINEERING DRAWINGS........ @ lat we
SERVICE LETIERS 4 is i og 6 9 @ 46 WEDS ES
SERVICE RECORDS ........ oe © we ©
SECTION 2. ANALYSIS OF OPERATION
FUNCTIONAL DESCRIPTION. .......---.--
DATA ORGANIZATION. ..... TT TITTY
BASIC TIMING .......----+2 02 eee
TIMING CHAIN... ....--2 0000 eee
COUNTER CIRCUITS... ..-..--02000-
DATA GHIPTING 4c cccs ex wus wea wees
DELAY TINE GCIROUTES sw ca wis was wise
Mon mssmscaen ue Lee eee
FUNCTION CONTROL ......----2-----
WAY ccc mee ecm scam ee
(IROL AR CIROUITE: w cs es ew gee ce we wc
BARIG DIRODEE cc p cs we ewe RE Rw E HS
FLIP-FLOP... 0... 00 eee eee eee
TOUTE, ok ce ee eek ee ew
EMITTER- FOLLOWER. 2. 06-0 ee eee
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
PAGE
di
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
PAGE
COUNTER CIRCULS 2. 28ims% See S BS KS 2-12
COUNTING: 25 Gi S5 SEEGERS BER dines ax 2-12
DATAUSHIN TING «2 ms 4 ck eam EB we ew 2-15
DELAY DINE CIRCUITS’: «2s ewes wee we oes 2-21
DELAY LINE 4 6) 64 6S 68 HSE SESE ES 2-21
TRANSDUCERS... 1.2... 2.2 eee eevee 2-21
READ AMPLIFIER ..........+.. 0040s 2-22
WRITE HOGI. oe: oo we oe ew GE eRe Te 2-24
WRITE: AMPLIBTER: is: ¢ = wi & 8 i BS wR KS 2-25
BASIC LOGIC 23 88 9S HERES mie me perne 2-27
ORGATE..... ee ee ee ee ee 2-27
AND'GATE, io: 2 6 eo ve HO @ WKS @ Rm HOH 2-28
AGIGATE «usu wee KE GOES HS BiG SS 2-28
LOGIC NETWORKS.............6.0-02. 2-30
LOGIC EQUATIONS. ...........000004 2-31
eG CN na ee RO ee ee Oe 2-32
OSCILGATBOR « a si ac ws oe we SES BERR BS 2-32
MACHINE START 6 6 666 8 Wea Sew ewe ne 2-33
FUNCTION START ..........-2.0000. 2-33
BET COUNTER, 9 ece: = a 6 & me KO Oh ww 2-34
REGISTER COUNTER. . 2. ee bre es F 2-36
COLUMN COUNTER: 52 #8 §% 82626 PRE BES 2-36
ROGIC CONTROL 6 iw ss BER DES BRE RE woe 2-40
ENTRY PHASE COUNTER(EPC),......... 2-40
DECIMAL POINT COUNTER (DPC) ........ 2-42
PUNGTION LOGO omicae ee we 8% ESE ES 2-45
BD a: ees ERE ETRE BRE RE aw eam: 2-45
SUBTRAGT 6 cs WEE REL Gene nee ame 2-51
MULTIPLY ..........20.00000 eae 2-59
Peed Ame ne oe E ee BUR © mK SRA & eS 2-71
NUMBER ENTRY oo cx: 6 swe eu i 8% 8 RUS HS 2-82
REPEAE eg 4 6 26 BLED REE Ree weve 2-85
RECALL © ii es ERE kw eww eer emunn 2-86
STORE... 1... . eee tee ee ee ee ee 2-88
CLEAR ENTRY. 0. «exe: & a: % @ mH BI EH BEE 2-89
CUANGE SIGN: ss sis sa SERRA Dew eax 2-90
CLEAR ALL.............0.00000004 2-92
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
PAGE
DISPLAY DEFLECTION . 6 1 20 6 se 6 ewe ewe 2-94
SEGMENT GENERATOR ...........2..4. 2-95
DOT GENERATORS «: 23 6 fe Be eG ke ER SS 2-96
SLANT AMPLIFIER. ..........-2.22-4- 2-98
VERTICAL STAIRCASE GENERATOR....... 2-98
HORIZONTAL STAIRCASE GENERATOR ..... 2-100
DEFLECTION AMPLIFIERS ............ 2-102
DISPLAY BLANKING .... 2... ee ee eevee 2-104
UNBLANKING INVERTER ........-2e+6-. 2-104
DIODE: MATRERs 6 6 v6 eee % 6 @ BB wr ew we 2-104
DISPLAY TIMING AND LOGIC ............ 2-110
DISPLAY TIMING. ... 2... eee eee eevee 2-110
DISPLAY GOGIC « w i a 26 isi & em: © wow 6 we ew 2-112
POWER SUPPLIES i 6 wi vo we & 6 tH & wR 6 KR BS 2-116
+6: VOLT SUPPLY « i & 64 § S56 2 ow FH ee ew 2-116
“12 VOLT SUPPLY & oi bb ye BS oa 6 Bl 8 se! SB ee 2-117
“80 VOLT: SUPPLY . 0: « «0 Cee te ee , 2-117
#2400 VOLT SUPPLY «eae e ane eae woe ew 2-118
GRE VOLTAGES ¢ 4 it 6 5% ee wR wT we 2-119
KEYBOARD FUNCTION. ......-.6-2 222 eo 2-121
GENERAL DESCRIPTION. ............. 2-121
CODE BARS i vw 0; 6 % 12 6% vay How a Hw wer Se we ww Ue 2-121
KEYBOARD INTERLOCEK:. «sh & owe HE aS 2-122
REED SWITCHES « «8 % we ewe ewe we ew 2-122
KEYBOARD ELECTRICAL FUNCTION. ...... 2-124
SECTION 3. ADJUSTMENTS
SCOPE OF SECTION 4 es @ ESLER GS ws 3-1
KEYBOARD ADJUSTMENTS ...... 2+ ee eee 3-1
EQUIPMENT REQUIRED. ......-2-+ 22+ 3-1
INITIAL: PROCEDURE 2 2 0 0 we 6 we wwe were 3-1
CD REED SWITCH « a: s a va 6 eee we ew wD we ww s 3-3
DIGIT KEY REED SWITCH. ........2.4.-.2-. 3-3
CF REED SWITCH ... ee ere ee ee nene 3-4
FUNCTION KEY REED SWITCH .........-. 3-4
CODE BAR ADJUSTMENT ......4.-+.-+44.-. 3-4
INTERLOCK ASSEMBLY ADJUSTMENT. ..... 3-6
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
iv
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
CHARACTER ADJUSTMENTS. ..........2..
SEGMENT LENGTH. .......205620250 2026.
CHARACTER WIDTH... « cece om © ie © wR Rw ay
CHARACTER HEIGHT «106 8 6 6 @ @ HH ww i
DISPLAY ADJUSTMENTS. ...... 6s ee eeee
HORIZONTAL CENTERING ............
VERTICAL CENTERING ..........2.+.4..
HORIZONTAL CHARACTER SPACING. ......
VERTICAL CHARACTER SPACING ........
READ AMPLIFIER GAIN ADJUSTMENT.......
SECTION 4. MAINTENANCE
KEYTOP REMOVAL AND REPLACEMENT...
DECIMAL POINT SWITCH REPLACEMENT... .
INTERLOCK ASSEMBLY ADJUSTMENT.....
CODE BAR ASSEMBLY REPLACEMENT .....
CODE BAR IDENTIFICATION ...........
KEYSTEM IDENTIFICATION. .....-......
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
PAGE
3-7
3-7
3-7
3-8
3-8
3-8
3-9
3-10
4-1
4-1
4-2
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
LIST OF ILLUSTRATIONS
NOTE: Figures not in chronological order with the text are Foldouts and will
be found at the end of each section.
FIGURE PAGE
1-1 ELECTRONIC CALCULATOR 130 ........2e+.0-e066 td
1-2 KEYBOARD ARRANGEMENT... 2. es erecereerves 1-2
2-1 OVERALL BLOCK DIAGRAM ...... 22.20 s es eees 2-128
2-2 DATA ORGANIZATION . 1... ce ecw ee ete twee 2-1
2-3 DISPLAY ORGANIZATION ... 2.2 eevee rcnrnncvens 2-2
2-4 TIMING, FUNCTIONAL DIAGRAM ........56.+6+04- 2-2
2-5 DISPLAY SHIFTING. . 2. 2 eee te te te wt ww es 2-4
2-6 DATA SHIFTING 2... -.6 6 68 6 8 ERS REDE MESS ES 2-4
2-7 DELAY LINE, FUNCTIONAL DIAGRAM ..........4.. 2-5
2-8 BASIC CHARACTER FORMATION .......-+424 50685 2-8
2-9 BASIC FLIP-FLOP CIRCUIT...... Sie BOW OT We ww GE wi % 2-10
2-10 BASIC COUNTER, FUNCTIONAL DIAGRAM.......... 2-13
2-11 DIGIT COMPLEMENT, FUNCTIONAL DIAGRAM ....... 2-14
2-12 SHIFT UP OR LEFT, FUNCTIONAL DIAGRAM ........ 2-17
2-13 SHIFT DOWN, FUNCTIONAL DIAGRAM ............ 2-18
2-14 IDLE CONDITION, FUNCTIONAL DIAGRAM.......... 2-20
2-15 DELAY LINE, PHYSICAL ARRANGEMENT .......... 2-20
2-16 TRANSDUCER, FUNCTIONAL DIAGRAM ........... 2-22
2-17 READ AMPLIFIER SCHEMATIC ..... 2.1 eee eevee 2-23
2-18 WRITE AMPLIFIER LOGIC... .. 2.5 ee ee eer e nee 2-24
2-19 WRITE AMPLIFIER SCHEMATIC. ........-2-+-+4+2e+8- 2-26
2-20 AC GATE, WAVEFORMS....... SVT TIPTIC TING 2-29
2-21. LOGIC NETWORK .: » «i 0 ee se ee ete eee em ee ee 2-30
2-22 MASTER OSCILLATOR SCHEMATIC. .......-4+58665 2-32
2-23 START LOGIC... .. + ee sees vsve ee ee 2-33
2-24 BIT COUNTER LOGIC. .. 1.2.21 ee eee eer eee tw eee 2-35
2-25 REGISTER COUNTER LOGIC. ....- 2s ee eee ee ees 2-37
2-26 COLUMN COUNTER LOGIC... 2... eee ee eet ee eee 2-39
2-27 ENTRY PHASE COUNTER (EPC)....... aw ey we ase oe e 2041
2-28 DECIMAL POINT COUNTER (DPC)... 1... +++ eee ees 2-43
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
ve
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
FIGURE PAGE
2-29 ADD FLOWCHART...........00+ 000 eevaee 2-129
2-30 SUBTRACT FLOWCHART............000000, 2-130
4°31 MULTIPLY FLOW CHART inci seu HERDER SES 2-131
2-32 DIVIDE FLOW CHART .........00000000 cece 2-132
2-33 DIGIT SELECTION LOGIC ............0+.e400e 2-83
2-34 DIGIT SELECTION FLOW CHART............... 2-133
2«30 ENTER PLOW CHART. wks cee aw tn wee ee wee ees 2-134
2-36 REPEAT AND RECALL LOGIC............-000.0. 2-87
2-37 REPEAT AND RECALL FLOWCHART............. 2-135
2-38 CLEAR ENTRY AND STORE LOGIC .............. 2-89
2-39 CLEAR ENTRY AND STORE FLOWCHART.......... 2-136
2-40 CHANGE SIGN LOGIC AND FLOW CHART. .......... 2-91
2-41 CLEARALL LOGIC ..............00000004 2-93
2-42 DEFLECTION CIRCUITS, COMPOSITE BLOCK DIAGRAM .. 2-137
2-43 SEGMENT GENERATOR SCHEMATIC ............. 2-94
2-44 SEGMENT SWITCHING SCHEMATIC.............. 2-95
2-45 VERTICAL DOT GENERATOR SCHEMATIC.......... 2-96
2-46 HORIZONTAL DOT GENERATOR SCHEMATIC ........ 2-97
2-47 SLANT AMPLIFIER SCHEMATIC. .............0.. 2-98
2-48 VERTICAL STAIRCASE GENERATOR SCHEMATIC...... 2-99
2-49 DEFLECTION VOLTAGE RELATIONSHIPS .......... 2-138
2-50 HORIZONTAL STAIRCASE GENERATOR SCHEMATIC .... 2-100
2-51 HORIZONTAL DEFLECTION AMPLIFIER SCHEMATIC... . 2-102
2-52 VERTICAL DEFLECTION AMPLIFIER SCHEMATIC ..... 2-103
2-53 UNBLANKING INVERTER LOGIC ............... 2-105
2-54 DIODE MATRIX SCHEMATIC. .............. » +. 2-106
2-55 MATRIX LOGIC..............2.2-0000004. 2-108
2-56 COMPARE SIGNAL LOGIC ..............2.. «. 2-111
2-57 DISPLAY LOGIC ..........0.0004 ee eeeae. 2-112
2-58 DECIMAL POINT SWITCH LOGIC ............... 2-114
2-59 POWER SUPPLY SCHEMATIC ................. 2-116
2-60 +6 VOLT SUPPLY SCHEMATIC ................ 2-117
2-61 -12 VOLT SUPPLY SCHEMATIC................ 2-118
2-62 -80 VOLT SUPPLY SCHEMATIC................ 2-119
2-63 -2400 VOLT SUPPLY SCHEMATIC......... c+ ee ee 2-120
2-64 MAGNET-REED SWITCH ACTION. .............. 2-123
2-65 KEYBOARD DELAY (KBD) SCHEMATIC............ 2-124
2-66 OVERFLOW LOGIC AND INTERLOCK COIL SCHEMATIC. . . 2-126
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
—
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
FIGURE
S-I KEYBOARD TESTER i ck wise SHED EER THC EEwWERG
38-2 KEYBOARD TESTER LAMP CHART...........266-.
3-3 VOM ADAPTER SCHEMATIC... ......+000 508+
3-4 VOM ADAPTER LAMP CHART. ......00800800486
3-5 REED SWITCH SADDLE ADJUSTMENE ......... eee
3-6 KEYSTEM ECCENTRIC CAM ADJUSTMENT. .........
3-7 CODE BAR LIMIT SCREW ADJUSTMENT ...........
3-8 INTERLOCK MAGNET LATCH ADJUSTMENT. ........
3-9 CHARACTER ADJUSTMENT CONTROLS. ...........
3-10 DISPLAY AND CHARACTER DIMENSIONS. ..........
3-11 DISPLAY ADJUSTMENT CONTROLS. .......-..-208.
3-12 READ AMPLIFIER ADJUSTMENT ........2025e006
3-13 READ AMPLIFIER ADJUSTMENT LEVEL...........
4-1 KEYBOARD MASK...... ee ee ee ees ce eee
4-2 KEYTOP REMOVAL. . «2.265 eee eae é Teo em RDO w Ve
4-3 KEYTOP REPLACEMENT, PRELIMINARY ..........
4-4. KEYTOP REPLACEMENT, FINAL...........-40.2.4.
4-5 DECIMAL POINT SWITCH REPLACEMENT..........
4-6 INTERLOCK ASSEMBLY ADJUSTMENT..........4..
4-7 KEYBOARD INNER PARTS PLACEMENT ...........
4-8 CODE BAR IDENTIFICATION CHART ........-+.4.4..
4-9 KEYSTEM IDENTIFICATION. .....-.-2-2¢ 222+ eee,
4-10 KEYBOARD TOP INSTALLATION .........-+.+..--.
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
vit
~~
9-1-65
FRIDEN ELECTRONIC CALCULATORS
SECTION 1
EC-130 SERVICE MANUAL
SECTION 1 - GENERAL DESCRIPTION
A. SCOPE OF MANUAL
This manual covers the maintenance of the
EC-130 (Figure 1-1). The maintenance of the
EC-130 requires extensive ‘and thorough know-
ledge of the machine, especially as to logic func-
tions. While most troubles are of a component
failure nature, localization of the trouble to a
particular component may involve extensive trac-
ing of logic signals through the plug in circuit
cards.
Since the EC-130 uses dynamic storage, and
the logic actions are predicated upon time through
the timing chain and Entry Phase Counter, know-
ledge of machine timing and proper use of a
Tektronix 535 Oscilloscope (or equivalent) is nec-
essary.
B. ELECTRICAL CHARACTERISTICS
The EC-130 operates on 115V +10% AC, 50-60
cycles, and may be connected to any standard AC
outlet. Specially designated machines for export
only are designed for operation at 220 VAC.
The EC-130 is fused internally with a 1 Am-
pere line fuse and a 2 Ampere fuse in the -12
VDC power supply output.
C. PHYSICAL CHARACTERISTICS
The EC-130 is 22" long, 18" wide, 10" high,
and weighs approximately 45 lbs. The relatively
small size of the EC-130 makes it suitable for
placement on any standard office desk, and the
light weight makes it truly portable.
D. OPERATIONAL DESCRIPTION
The operation of the EC-130 is controlled by
an ON-OFF switch lever located on the lower
front right-hand side. Once the lever has been
placed to ON position and the display appears on
the CRT, the EC-130 is ready for keyboard control.
1. DISPLAY
The display on the EC-130 consists of four 13-
digit registers, each with an algebraic sign col-
umn. No sign displayed means a positive number
in that register. If the number is negative, a
minus sign is displayed in the extreme right-
hand position of the register.
The EC-130 employs a new concept in compu-
tation which permits storage of intermediate
answers for later use according to the require-
ments of the problem being solved. The four reg-
isters are specified and arranged in a particular
manner. (See Figure 1-1.)
a. REGISTER #1. The lowermost register is des-
ignated as Register 1, also known as the “An-
swer Register”. All numbers enter the display
through this register, and are displaced upward
by subsequent entries. At the finish of any arith-
metic function, the answer to the computation
appears in Register 1. This register is also
brightened with respect to the other registers.
R4
R3
DISPLAY
R2
R14
ON-OFF SWITCH
(HIDDEN)
KEYBOARD
Figure I-1. Electronic Calculator 130
1-1
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
SECTION 1
FRIDEN ELECTRONIC CALCULATORS
9-1-65
EC-130 SERVICE MANUAL
b. REGISTER #2. One of the numbers of an
arithmetic operation is in this register; the other
number is in Register 1. When the numbers in
these registers are used in an arithmetic opera-
tion, the answer appears in Register 1, and the
numbers in Register 3 and 4 are automatically
shifted down by one register.
¢. REGISTERS #3 AND #4. These registers
are used for storage of numbers, or intermediate
answers. When the lower two registers are used
for computation, these registers shift down one
register with the previous Register 3 number be-
ing placed in Register 2 and immediately avail-
able for further computation. If Register 1 is
used for an entry (or Recall, or Repeat) when all
registers already contain numbers, the contents
of Register 4 shift up and are effectively dis-
carded, or lost.
2. KEYBOARD
The keyboard (Figure 1-2) is the only mechan-
ical portion of the EC-130. When a key is pres-
sed, the mechanical motion of the key is trans-
lated into the closing of one or more switches
that initiate the electronic action of the machine.
FUNCTION
KEYS
DIGIT
ENTER key need not be used except in the enter-
ing of more than one number with no other func-
tions being performed between the number entries.
DECIMAL POINT key is used when entering a
number containing a decimal. If DECIMAL POINT
key is not used, the number is sensed as a whole
number and decimal aligned to the left of the deci-
mal point.
An automatic “Decimal Interlock” feature is
provided that prevents entering more decimal
digits than can be accomodated after decimal
alignment. Assume a decimal point position set at
2, then only two digits to the right of the decimal
point can be utilized. The third and subsequent
digits entered after DECIMAL POINT key is
pressed are automatically disregarded.
b. FUNCTION KEYS. The function keys are
designated as those keys that rearrange the data
on display, or initiate arithmetic operations upon
the data in Registers 1 and 2.
(1) ENTER - The ENTER key completes a
number entry by decimal aligning Register 1.
DEC. POS.
THUMBWHEEL
FUNCTION
KEYS
KEYS
Figure 1-2. Keyboard Arrangement
a. DIGIT KEYS. On the keyboard are 10 digit
keys (0 - 9) and a decimal point key that enable
entering numbers in the machine, As a number
is entered in the machine by sequential depres-
sion of the digit keys, that number appears digit
by digit in Register 1, but without the decimal
point,
The completion of a number entry is signified
in the machine by pressing ENTER key, which
then decimal aligns the entered number. Initia-
tion of any function also aligns the number in
Register 1, if not already aligned. Therefore,
1-2
(2) STORE - The STORE key places the num-
ber in Register 1 into an undisplayed storage
register. Once the number is stored it can
be recalled as often as desired but is not
changed except by replacement with a new
number, or by pressing CLEAR ALL key,
which removes all data.
(3) RECALL - The RECALL key duplicates
in Register 1 the number that is in the stor-
age register.
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
9-1-65
FRIDEN ELECTRONIC CALCULATORS
SECTION 1
EC-130 SERVICE MANUAL
(4) REPEAT - The REPEAT key duplicates
in Register 2 the number that is in Register 1.
(5) ADD (+) - The Add key initiates machine
action that results in the numerical addition
of the numbers in Register 1 and Register 2,
with the result (answer) appearing in Register
1. When the answer appears in Register 1,
numbers in Registers 3 and 4 are displayed
as shifted down by one register.
(6) SUBTRACT (-) - The Subtract key in-
itiates machine action that results in the
numerical subtraction of the number in Reg-
ister 1 from the number in Register 2, with
the answer appearing in Register 1 and num-
bers in Registers 3 and 4 shifting down. If
the number in Register 1 is larger than the
number in Register 2, the subtraction still
takes place. However, before display, the
numerical result is complemented and then
displayed with the sign changed.
(7) MULTIPLY (X) - The Multiply key ini-
tiates machine action that results in the
numerical multiplication of the number in
Register 1 by the number in Register 2 with
the answer appearing in Register 1, and
the numbers in Registers 3 and 4 shifting
down.
(8) DIVIDE (+) - The Divide key initiates
machine action that results in the numerical
division of the number in Register 2 by the
number in Register 1, with the answer ap-
pearing in Register 1 and the numbers in Reg-
isters 3 and 4 shifting down by one register.
c. ADDITIONAL KEYS. In addition to the digit
keys and function keys are keys that initiate ma-
chine operations such as clearing Register 1,
clearing all data, etc.
(1) CLEAR ENTRY - The CLEARENTRY key
initiates machine action that results in the
removal of the number in Register 1, usually
in the case of a mistake being made during
a number entry.
(2) CLEAR ALL - The CLEAR ALL key in-
jitiates machine action that results in the re-
moval of all numbers from the machine. This
includes any number in storage, as well as
on the display.
If the machine is turned off, or power to
the machine is interrupted for any reason,
this also results in the removal of all data.
Courtesy of The Old Calculator Museum
(3) CHANGE SIGN - The CHANGE SIGN key
initiates machine action that results in chang-
ing the sign of the number in Register 1. When
a number is entered, it is sensed as a posi-
tive number. Certain mathematical opera-
tions involve the use of negative numbers, and
the Change Sign function enables the number
to be made negative after the number is en-
tered. The CHANGE SIGN key also enables
the sign of the number in Register 1 to be
reversed at any desired point during a com-
plex mathematical operation.
(4) OVERFLOW LOCK - If a number that is
entered, or an answer developed, contains
more whole number digits than there are
columns to the left of the decimal point when
the number is decimal aligned by ENTER key
or during a function, OVERFLOW LOCK lights
up and the keyboard locks-up, which desig-
nates an entry, or an answer, larger than
machine capacity.
The overflow condition can be cleared by
any one of three keys: CLEAR ENTRY,
CLEAR ALL, or OVERFLOW LOCK. CLEAR
ENTRY removes the overflow by removing
the number in Register 1, which is theentry,
or answer, that caused the overflow. CLEAR
ALL removes the overflow by clearing all
numbers from the machine, which includes
the entry, or answer, that caused the over-
flow. OVERFLOW LOCK removes the key-
board lock-up without clearing any numbers,
which leaves a portion of the entry or the
answer displayed in Register 1.
E. DECIMAL POINT SELECTOR
On the right-hand side of the keyboard is a
thumb-wheel which permits selection of the col-
umn position of the decimal point. There are five
positions available: 0 - 2 - 5 - 7- 13. A field
option is available that changes position 7 to po-
sition 9.
Once the decimal position is chosen with this
wheel, automatic decimal alignment of all entries
and answers takes place with respect to this
position.
F. SERVICE CALLS
Many of the repairs and adjustments to the
EC-130 are accomplished in the customer’s office.
Following are certain servicing procedures that
may prove useful, not only to the beginning tech-
nician but also to the more experienced.
http://oldcalculatormuseum.com
SECTION ]
FRIDEN ELECTRONIC CALCULATORS
9-1-65
EC-130 SERVICE MANUAL
1. CUSTOMER CONTACT
A Service Technician is probably the most
often seen representative of the Company, espe-
cially at the office “working” level as distinguish-
ed from “management”. As such, it is important
that the technician be neat, well-groomed, and
courteous.
Competition is keen in the office equipment
field. Often, the choice between competing ma-
chines is the service factor. As a part of the
service organization, the service technician is
an important representative and should look,
act, and conduct himself as such, It is not enough
just to be a good technician; to know the machine;
or to be able to adjust the machine satisfactorily.
It is also very important to leave the customer
satisfied, not only that the machine is working
well, but also that he has been treated with re-
spect; his wishes have been courteously received
and complied with to the maximum practical ex-
tent; and that the whole servicing procedure was
conducted by aneat, efficient, courteous, and well-
trained representative.
As a part of customer contact, the technician
must find out, as courteously and expeditiously
as possible, the cause of customer complaint.
Very often, courteous listening to the machine
operator, even if not directly applicable to ma-
chine malfunction, will leave a very good impres-
sion. The first step in service procedure is to
find out what is wrong from the standpoint of the
customer.
2. MACHINE CHECKOUT
Machine checkout is a series of semi-standard-
ized steps used in determining a machine mal-
function. Necessarily, experience with the EC- 130
will enable each service technician to develop
his own checkout procedures. The following is a
guide to be used if desired.
a. AC POWER. Since the EC-130 is anelectronic
machine, it must be furnished with AC power at
115V, 50-60 cycles from a convenient 3-wire,
grounded, AC outlet. One of the first steps ina
checkout is to determine if power is being fur-
nished to the machine, especially if the prelimin-
ary inspection reveals a blank display.
On the right hand side of the machine, beneath
the top cover, are two fuses. The best check of
the fuses is to replace them with two known good
fuses of the same type and current rating.
On the bottom front right side of the machine
is an On-Off switch. To turn on the machine, this
switch is placed forward. The On-Off switch is
interlocked with the right hand top-cover holding
screw. (See Top Cover Removal and Replacement
Procedure.)
b. VISUAL INSPECTION. Visual inspection of the
display can reveal malfunctions such as character
malformation, displacement, and abnormal height
or width. There are two purposes in the design
of the display. One is to provide ameans of visu-
ally checking the numbers to be operated with,
and the second is to provide a clear and pleasing
visual presentation. Certain aspects of the visual
presentation are adjustable to customer satis-
faction if desired. Visual display adjustments are
covered in Section 3 of this manual.
c. STANDARD PROBLEM. Following is astand-
ard problem that will check most of the functions
of the EC-130; Decimal Point Selector on0:
(1) Press CLEAR ALL
(2) Press digit 1-1-1-1-1-1-1
(3) Press ENTER
(4) Press STORE
(5) Press RECALL
(6) Press REPEAT
(7) Press Multiply (X)
Register one shows:1234567654321
Enter, Store, Recall, Repeat, and Multiply
are checked in the above procedure.
(8) Press RECALL
(9) Press Divide (+)
Register one shows:0000001111111
Divide is checked.
(10) Press REPEAT
(11) Press Add (+)
Register one shows:0000002222222
Add is checked.
(12) Press RECALL
(13) Press Subtract (-)
Register one shows:0000001111111
Subtract is checked.
(14) Press “0”
(15) Press Divide (+)
Display remains blanked.
Unsolvable problem, answer would be infinity.
(16) Press CLEAR ALL
(17) Move Decimal Point Locator to 7 on dial.
(18) Press digit: 1-1-1-1-1-1-1
(19) Press ENTER
1-4 Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
9-1-65
FRIDEN ELECTRONIC CALCULATORS
SECTION 1
EC-130 SERVICE MANUAL
OVERFLOW LOCK lights, keyboard locks-up.
Entering of too many whole number digits is
checked.
(20) Press CLEAR ENTRY
(21) Move Decimal Point Locator to 2 on dial.
(22) Press digit: 1-1-DECIMAL POINT-1-1-1
(23) Press ENTER
Register one shows: 00000000011.11
Entering of too many decimal digits is
checked,
G. SERVICING DOCUMENTATION
In addition to the Service Manual are other
documentary aids to servicing of the EC-130.
They are listed and briefly explained as follows:
1. COMPUTER PRINTOUT (MDD)
The computer printout is the basic engineering
documentation of the EC-130. This type of docu-
mentation will also be used for later machines
in the design progression. As such, it contains
authoritative information in a concise form that
lends itself easily to changes, extraction of pro-
duction information, part number and locationin-
formation, and a coherent method of logic analysis
by use of a specialized logic equation format.
a. BASIC MDD. The Computer Printout (MDD),
as reproduced for service use, contains four
parts: Glossary of Terms, Logic Equations, Con-
struction File, and Schematic Diagrams.
(1) Glossary of Terms. The glossary lists in
alphabetical order all of the logic terms used
in the logic equations. The glossary further
provides the number of the equation that pro-
duces the term, a list of equations that con-
tain this term, and a brief description of the
term.
(2) Logic Equations. The equations section
contains the logic that produces each listed
term in the glossary. The equations are
written in a specialized form called “Modi-
fied Polish Notation”. The equations section
also contains location information in a visual
coordinate system that permits the location
of a signal reference point for any of the logic
terms or gates referenced in a particular
equation.
(3) Construction File. The construction file
contains production information useful in pro-
viding drilling coordinates, insertion coor-
dinates, lead orientation, etc. The main use
of the construction file is to provide the ser-
vice technician with component information
on each element that makes up the logic,
especially the part number of the component
parts.
(4) Schematic Diagrams. Certain analog cir-
cuits such as the Power Supplies, Display
Deflection Circuits, etc. do not lend them-
selves easily to logic equation form or co-
ordinate component location. Therefore,
these circuits are furnished in schematic
diagram form. The schematic section also
contains wire lists, visual X-Y coordinate
card pictures, and other information of use
to the servicing technician.
2. LOGIC BLOCK DIAGRAM
To aid in the training of technicians and the
servicing of the EC-130, a Logic Block Diagram
has been evolved from the information contained
in the Computer Printout.
The Logic Block Diagram contains the logic
of the EC-130 in the form of gates, inverters,
FF’s, and other elements. The layout of the Logic
Block is primarily designed for ease of training,
but is also extremely useful in servicing.
The Logic Block Diagram also contains visual
coordinate information to enable a servicing tech-
nician to trace a logic fault back to an originating
element by means of an oscilloscope in a rapid,
time-saving manner.
3. ENGINEERING DRAWINGS
The production of the EC-130 necessitates en-
gineering drawings regarding assembly, compo-
nent layout, etc. Such of these drawings as are
thought useful in servicing are available as re-
quested. Usually, the engineering information is
furnished to the technician by means of parts
lists, service letters, and service correlation of
engineering drawings.
4, SERVICE LETTERS
In the event that it is desired to get an engin-
eering change into the field documentation im-
mediately, a Service Letter is prepared contain-
ing all pertinent information.
The Service Letter is also used to convey
special repair techniques, common trouble notes,
and other servicing information of value to the
technician,
The Service Letter file should be well kept
and each technician should be thoroughly familiar
with the contents.
1-5
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
SECTION 1
FRIDEN ELECTRONIC CALCULATORS
EC-130 SERVICE MANUAL
H. SERVICE RECORDS
The Procedures Manual contains the latest
promulgated method for handling specific service
records, and other service office documents.
However, the ordering of service documentation
is an area of special attention.
To order an engineering drawing, the engineer -
ing number of the drawing must be given. To
order a service produced document, the service
numbering system must be used. For example,
on each reproduceable page sized drawing in the
Service Manual is a number such as D-130-82T.
To order a drawing, this number is used.
Drawing Number Format:
D_ ~- Designates a drawing; A “P” would
1-6
9-1-65
designate a photograph.
130 - Model Number.
82 - Identification number in a series of
numbers.
T - Information and format developed by
Technical Servicing Group at Home
Office. An “E” would designate an en-
gineering drawing which has been re-
drawn by service. A “W” would desig-
nate a drawing which was originated by
the Technical Writing Section for use
in a manual.
In the event that a photograph, or less-than-
page sized drawing appearing in a manual is
desired, reference to the manual section and
page is sufficient.
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
9-1-65
FRIDEN ELECTRONIC CALCULATORS
SECTION 2
EC-130 SERVICE MANUAL
SECTION 2 - ANALYSIS OF OPERATION
A. FUNCTIONAL DESCRIPTION
The functional description of the EC-130 is a
brief explanation of the major functional circuits
on a block diagram level, with reference to the
Overall Block diagram, Figure 2-1.
(NOTE: Figures not in chronological order with
the text are Foldouts and will be found at the end
of this section.)
1. DATA ORGANIZATION
The data is organized in the machine by the
action of timing signals on the counters. The action
of the counters controls the placement of data on
the delay line, and on the CRT display. The CRT
le
displays datain aspecific pattern (See Figure 2-2).
Some of the data relationships in the machine are
not displayed but are used for necessary arith-
metical, storage, or timing operations. The major
time relationships in the machine are: Bit time,
Register time, Column time, and Word time.
a. BIT TIME. Each R time is composed of six-
teen (16) Bit (B) times, of which nine (9) are used
for pulses that represent digits. One B time is
equal to 3 psec.
b. REGISTER TIME. There are six register (R)
times, of which four are displayed (See Figure
2-3). Each R time is equal ‘to 48 psec. Each
register time can contain one digit of a number.
2868p SEC
TIME
co] ci |c2 |c3|ca|cs |ce|c7 [ce l|cs|ciofci jci2]
\
to"
WORD TIME —
ci3}ci4|cis|co
/
—eo| je—a7psec.
IL |
7
‘.
/
START PULSE
{COR3B3)
48SEC
/ \
[rs |ro| Ri | r2|R3 [Ra |
--" 1 a,
oa ' wn eect
aa ' TH
syste BER ces =
-_—- 1 ac
er el $B SSL
ogGnarn iid
spams ' a
aren as ! ian eS
< RI TIME (16 BIT TIMES) ole R2 TIME (16 BIT TIMES) +
|
so | 5: | 82 | 83] 54/65 | B6 aiauenwi ae a Bo] si | 82 Tee el 88 a Bi |ei2| a3 |ei4 "|
BIT ;
TIME
3p) SEC
COUNT OF 9 COUNT OF 4
; T
| phate mci =e
| \
i} !
© 0 0 00 0:0 00 00 0 0 R4
\ © 0 0 0 0 0} 0 0 0 0 0 0 O R3
0 00 00 04 0 0 0 0 0 0 R2
! © 00 00 0989 00 00 0 0 RI
4
a a
cl4 ci3 ci2 cll ClO C9 C8 C7 C6 CS C4 C3 C2
CRT DISPLAY
DISPLAY
TIME
cl
)\ pesemve FOR
1 SIGN OF REGISTER
D130-29W
Figure 2-2. Data Organization
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
SECTION 2
FRIDEN ELECTRONIC CALCULATORS
9-1-65
EC-130 SERVICE MANUAL
cis|cialcisicizlci |ciol colca |c7lcelcs lcales |c2l cilco
<< CRT DISPLAY TIME
| pei’ pispLay 3 DiGits)-———» ’ Lae.
#————COLUMN TIME (i6 TOTAL, 4 DISPLAYED)
R4_
.R3_
R2 REGISTER TIME
(6 TOTAL, 4 DISPLAYED)
RI
RO
SIGN
DISPLAY
Rs_
Figure 2-3. Display Organization
c. COLUMN TIME. There are a total of sixteen
(16) column (C) times, of which fourteen are dis-
played on the CRT. Each column time is equal to
288 psec. One column (C1) is reserved for display-
ing the algebraic sign of the register. Columns
two (C2) through fourteen (C14) display digits for
each register. Thus, a total of thirteen (13) digits
may be displayed in each register. Column fifteen
(C15) is used in a divide operation, and column
zero (CO) is not used.
d. WORD TIME. Word time is used to identify
the total time available for a sequence of data.
Word time consists of the six register times
multiplied by fifteen column times.
2. BASIC TIMING
The organization of the data on the delay line,
the positioning of the data on the display, and the
sequence of internal machine operations are all
related exactly by timing signals from the timing
circuits (See Figure 2-4),
DISPLAY DISPLAY
OSCILLATOR CIRCUITS COUNTER
|
CLOCK "B" TIME "R" TIME "Cc" TIME
FF rT COUNTER COUNTER COUNTER ei
"R" TIME "Cc" TIME
Laer (16 "8" TIMES) (6 *R* Times)
SYNC nome Le. END OF CIS TIME
Figure 2-4. Timing Functional Diagram
Courtesy of The Old Calculator Museum
http://oldcalculatormuseum.com
9-1-65
FRIDEN ELECTRONIC CALCULATORS
SECTION 2
EC-130 SERVICE MANUAL
a. SYNC PULSE. To maintain the relationship
between the delay line and the timing circuits, the
timing chain is stopped at the end of C15 time.
This begins a period of time designated as “Home”.
When the machine is prepared for the entry of data
after having first been turned on, or whenever all
data has been cleared from the machine by CLEAR
ALL key, a Sync pulse is placed on the delay line
by the first function initiated by the keyboard. This
Sync pulse is timed to occur before C1 time, and
turns on the timing chain just before datais avail-
able at the output of the delay line. This ensures
that the timing chain is always in step with the
data, and thus the data can be identified correctly
by timing chain signals.
b. CLOCK CONTROL. The basic time elementis
the frequency of the oscillator. The oscillator out-
put drives the clock circuit, which puts out one
pulse each Bit (B) time. While the oscillator runs
continuously, the output of the clock is stopped at
the end of C15 time. The clockis started again by
the action of the Sync pulse at the time the first
data is available at the output end of the delay
line. This keeps the timing chain and the data
synchronized so that the timing chain signals can
be used to exactly identify the data by time as it
comes off the delay line; and also while it is in
the counter circuits.
3. TIMING CHAIN
The timing chain is agroupof FF’s that develop
the basic time relationships in the machine. Tim-
ing signals from the timing chain enable the data
to be organized in a specific sequence and arith-
metical and data shifting operations to be per-
formed at specified times that are time-related
to the data sequence.
a. BIT TIME COUNTER. The B time counter
circuits count the clock down by sixteen and pro-
vide an output pulse to the Register (R) time
counter every sixteen (16) B times.
b. REGISTER TIME COUNTER. The R time
counter circuits count down the output of the B
time counter circuits by six, and provide an out-
put pulse to the column (C) counter circuits every
six (6) R times.
c. COLUMN TIME COUNTER. The column (C)
time counter circuits count down the output of the
R time counter circuits by 16, and provide an out-
put pulse every sixteen (16) C times.
d. DISPLAY CONTROL COUNTER. The display
counter provides signals to the display circuitry
that enable each register to be displayed at the
Courtesy of The Old Calculator Museum
necessary time and proper position on the CRT.
Register one (R1) is displayed twice for extra
brightness and this is desirable, since the answer
to an arithmetical operation always appears in
this register.
4, COUNTER CIRCUITS
The counter circuits perform two functions:
counting and shifting. Both are basic to machine
operation. Counting means to progressively
change the setting of a counter by the one-by-one
addition of pulses, which is called “Serial Entry”.
There are two similar types of counters: Up
Counter and Down Counter. They are capable of
ten possible counts (settings).
a. UP COUNTER. The addition of a pulse to an
up counter causes the setting to change in an up-
ward direction from zero toward nine. Thus, one
pulse into an up counter already set to three (3)
results in a new setting representing four (4).
b. DOWN COUNTER. The addition ofa pulse into
a down counter will cause the setting to change in
a downward direction from zero (representing 10)
toward one. Thus, one pulse into a down counter
already set to three (3) results in a new setting
representing two (2).
5. DATA SHIFTING
Data shifting means to change the position of
data with respect to time. To shift is to transfer
the setting of one counter into another counter.
Since the shift (transfer) of datais controlled with
respect to time, the datacan be moved with respect
to time by shifting into specified counters.
Before explanation is made of the specific shifts
used in machine operation, reference must be
made to dataorganization with specific application
to shifting.
a. DATA SEQUENCE. The data organization,
called “data sequence”, is by register time and
column time, both on the display (Figure 2-5) and
on the delay line (Figure 2-6). Note that all R
times in C2 occur before the R times in C3, the
R times in C3 before the R times in C4, etc.
To move data from R1 to R2, the data must be
stored (delayed) until R2 time occurs. To move
data from R2 to R1, thedata must be moved ahead
in time (advanced) because R1 occurs before R2,
To move data from a register in C2 time to the
same register in C3 time, the data must be delayed
(stored) until that C3 time occurs. The delay or
advance in time is determined by the type of shift.
2-3
http://oldcalculatormuseum.com
SECTION 2
FRIDEN ELECTRONIC CALCULATORS
9-1-65
EC-130 SERVICE MANUAL
|
|c14|—_-—- —|es|ea|c3|calci] ci tiMe
ry mt FOR SIGN
R4
R3
-<— DISPLAY =~ SHIET
R2
| RI
| | | | Ro SHIFT
ae ag) ag/ DOWN
NL”
SHIFT LEFT Rs
TIME<—
fe)
Figure 2-5. Display Shifting
b. SHIFT UP. To shift up means that onthe dis-
play (See Figure 2-5) the registers will move up:
R1 data to R2, R2 data to R38, R3 data to R4, and
R4 data will be lost. However, in terms of data
|» TIME
c2
SHIFT SHIFT
DOWN uP
{\
c3
SHI